IPL works on the theory of photothermolysis. This occurs when light is absorbed into excess melanin (dark pigment) in your skin and haemoglobin (red colour of your blood vessels). Cold gel is applied to the skin and your eyes are protected. The smooth glass surface of the hand piece is gently placed on your skin and pulses of light are applied. In the skin, the light converts to heat, which damages the abnormal dark or red skin cells whilst leaving the surrounding skin less affected. The pigment cells will naturally move toward the surface of the skin and slough off leaving a lighter, less visible lesion. The red lesions (veins, rosacea) will gradually fade over time.
---Specification---
Model | E9C - Elva |
Screen | 8.4 FTF true color LCD display (24bits for color) |
Output power | 2000W |
Frequency | 1~10Hz adjustable |
Energy | SHR 1~20J/cm2; OPT 1~50J/cm2 |
Handle | 640~950nm |
Spot size | 8*40mm/10*40mm/15*50mm/15*35mm optional |
Pulse number | 10~100 adjustable |
Cooling level | -5℃~0℃ |
Xenon lamp | Double American lamps with 1,000,00 shots in each one, strong energy |
Connector | Imported Germany connector |
Number of handle | 1 SHR handle and 1 OPT handle |
Cooling system | semiconductor+ air + water + cooling gel |
Voltage | 220V/110V |
Package | Aluminum alloy case |
Package size | 83*55*55cm |
---Operate Guide---
Operation
Hair Removal
◆ Clean Skin
◆ Cut short hair length less 1CM
◆ Smear cooling Gel
◆ Adjust correct parameter
◆ Keep Laser shoot not hurt to eyes
◆ Treatment on skin until skin become red
◆ Finish operate ,cooling skin avoid smear(30minutes )
Notice
◆Except for the staffs who have got the permission from our company , any other person are not permitted to repair the E-LIGHT System ,esp. the inner part of the machine , Including the power 、cooling system 、optics components and treatment head .
Notice. : The machine has dangerous high pressure.
◆Please notify the volt (220V/50Hz 110V/60Hz)identical with your country .
◆Only when the machine is power-off , then the repair can be made . The repair under the machine with electricity will be harm to machine and dangerous to people.
◆Keep the crystal clean all the time , it should not let the cooling gel or other liquid enter the treatment head .
◆When u found the treatment head leaks water . You should not open the machine. If u already has opened it, you should stop the machine immediately.
WHAT OUR CLIENTS SAY
A hair removal device with flash function. First of all very portable. Allows you to save a lot of space. Secondly, the hair removal effect of this instrument is very significant and the hair removal effect is relatively long.
What to do after treatment?
◆ Avoid exercise that will create friction and make sure to gently pat off any sweat
or water to dry the skin under your dressing.
◆ For the first 3 days after treatment, keep the treated area bandaged with sterile
gauze and protected with a thin layer of antibiotic or healing ointment.
◆ After 3 days, keep the treated area clean and dry during the healing processIt
is recommended to wait at least six weeks after gettinga new tattoo to begin
the laser tattoo removal process.
As we all know
◆ mild redness and warmth to the treatment area
◆ mild redness and warmth to the treatment area
◆ swelling of the hair follicle following hair reduction treatments
◆ tingling and/or itchiness of the skin lasting up to several days following hair reduction treatments
◆ a temporary increase in hair growth and hair regrowth that is finer and lighter following hair reduction treatments
◆ initial darkening of pigmented spots following skin colour adjustment treatments
◆ mild swelling and/or bruising following skin colour adjustment or capillary reduction procedures.
Equipment daily maintenance
◆gently, does not put the instrument placed in direct sunlight
◆regularly with a dry towel clean surface, machine parts surface dust and dirt.
◆before and after each use will probe cleaning and disinfection (wipe the surface with a 75% medical alcohol, prohibit the use of alcohol)
◆to prevent cross infection, each operation probe for personal use!
<<Previous page
Next page >>
2 handles ipl hair removal tattoo removal beauty equipment E9SQ
View More >Shr Dpl Permanent Ipl Hair Removal Machine Sapphire Freezing Point DPL04
View More >DPL SHR IPL Hair Removal Skin Rejuvenation Vertical Beauty Machine H8B
View More >Hot Sale>>>
Similar product:E11C professional IPL epilation and Q-switch tattoo removal equipment
More choice:808nm diode laser / diode laser hair removal / permanent hair removal - Y8B
Cooperative agencies
Product:
The Global Beauty Group is registered under the China Cooperation Act,2008 Business Number 91110115674295685F.